Efisiensi Kapasitas Lentur Beton Pracetak (U-Ditch) Dengan Model Dinding Corrugated

Authors

  • Erwin Syaiful Wagola Iqra Buru University
  • Muhammad Tharik Kemal

DOI:

https://doi.org/10.21776/ub.rekayasasipil.2020.014.02.3

Keywords:

U-Ditch, Corrugated, Eficiency Of the corrugated

Abstract

This study discusses to analyze the flexural capacity and efficiency of the corrugated U-Ditch type with dimensions of 50x50 cm to the normal U-Ditch type. In this research using JIS (Japan International Standard) method for The U-Ditch Corrugated test. The results showed that the flexural behavior of the Normal Type U-Ditch is linear to collapse with a crack pattern occurring on the U-Ditch wall.  The bending of the U-Ditch Corrugated type tends to be linear until it collapses with a crack pattern occurring in the structural wall. The magnitude of the bending moment capacity for the normal type is 9.11 kN.m and capacity of the U-Ditch corrugated type is 8.05 kN. m where the efficiency of bending capacity is 98%.

References

. Erwin Syaiful Wagola, at. all. (2017), “Kapasitas Lentur Sluran Drainase Pracetak U_Ditch†Jurnal Sains & Teknologi Vol. 6 No. 1 ISSN 2303-3614. Hal. 1-103.

. Elliott K. (2002), “Precast Concrete Structuresâ€, Butterwoth-Heinemann.

. Japan International Standard, “Reinforced concrete gutters for roadsideâ€, JIS A 5345.

. Japan International Standard, “General rules for methods of performance testâ€, JIS A 5363.

. Rohit B., Nimse., Digesh D., Joshi & Patel P.V. (2014), “Behavior of wet precast beam column connectionsunder progressive collapse scenario: an experimental studyâ€, Int J Adv

SNI-03-2847-2002, “Tata Cara Perhitungan Struktur Beton Untuk Bangunan Gedungâ€..

Downloads

Published

2020-06-30

How to Cite

Wagola, E. S., & Kemal, M. T. (2020). Efisiensi Kapasitas Lentur Beton Pracetak (U-Ditch) Dengan Model Dinding Corrugated. Rekayasa Sipil, 14(2), pp.99 – 103. https://doi.org/10.21776/ub.rekayasasipil.2020.014.02.3

Issue

Section

Articles